Arrived to inspect unit not heating the back of the building. Inspected units in heat test mode. Inspected order of operation and found unit 2 to not be heating. Found unit tripped off on pressure switch fault. Inspected pressure switch air hose and found blockage stoping air flow. Cleared blockage and reset system. Unit now heating properly no faults job complete.

Near Eastern Blvd, Essex, MD 21221
Joseph.Wade@supremeairllc.com

[email protected]

Fall tune up 9/17/19 when I arrive system was off customer asked me to check it and heat, and cooling. Area where I was working was very tight and difficult to get to. I check electrical components check voltage and amps. I also checked for leaks filter was changed previously before I got there system OK check airflow return air 118° return 75

Near Cedar Valley Pl, Essex, MD 21221
Joseph.Wade@supremeairllc.com

[email protected]

Fall tune up 9/17/19 when I arrive I said call for heating measure airflow measure return air check voltage checked electrical components check amps. Check filter and coils everything’s all OK

Near Cloverwood Ct, Essex, MD 21221
Colin T.

Colin T.

Performed Inspection on both RTUs. Replaced all filters. Unit 1 drain Trap was clogged, overflowing. Cleaned trap and pipe, drain clear and emptying properly. Flushed out unit 2 drain as well. Found Inducer motor running on unit 1. Found shorted wire caused unit to fire and it locked out on false flame sense. Repaired wire and inducer/heat stayed off when I returned power. Inspected belt, blower wheel, Evap and condenser coils. All clean, belts good. Checked capacitors and contactors, tightened electrical connections. Ran both stages of ac on systems. Measured amp draw and delta air temps. Both units operating normal at this time.

Near Eastern Blvd, Essex, MD 21221
Yonas M.

Yonas M.

Service call on 07/17/19 on arrival customer explained to me thermostat gave the error code condenser drain clogged set unit to call for cooling the unit running fine but when I open the Evaporator coil the drain pan is full of water I tested with water the water is not going out I gave quote for customer cleaning the condenser drain line with nitrogen pressure customer accepted cleaned the condenser drain line tested water is moving out very smoothly checked electrical connections checked voltage and amps measured supply and return air temp checked water pressure and water temp it was low I was pump it back up to 55/50 psi unit operating normal at this time. Collected $89.00. For dispatch fee and $283 for cleaning the condenser drain line with nitrogen total $372.00 on C.C

Near Cape May Rd, Essex, MD 21221
MarkM@supremeairllc.com

[email protected]

Installed new compressor safety. Made all wiring connections. Checked operation.

Near Old Turkey Point Rd, Essex, MD 21221
Christopher A.

Christopher A.

Copeland diagnostic device is faulty. No safety devices were open and the device had 24 volts but would not power on. I bypassed for time being and completed a parts order form for the device.

Near Old Turkey Point Rd, Essex, MD 21221
roberts@supremeairllc.com

[email protected]

Tied new water heater to existing connections. Tested its

Near W Rd, Essex, MD 21221
roberts@supremeairllc.com

[email protected]

Water heater electric 50 gl. Replacement. Paid 700 in cash to me. Will hand to Jackie. Will schedule for Monday

Near W Rd, Essex, MD 21221
Christopher A.

Christopher A.

I operated the unit on heating mode and found it was slow to heat and only heated by 10-15 degrees. The auxiliary heat worked properly. I checked the electrical wiring and electrical systems, all are within specification. I went to the outdoor unit and found refrigerant pressures were low even after I forced the defrost. I quickly identified a slow leak out of one of the valve stems. I tightened this but the unit is still around 3lbs low on refrigerant. I gave the customer a price to recharge while I wan on site but customer declined at this time. I explained I would have to put an additional estimate in the system reflecting a return trip to charge the unit. Customer unable to complete the repairs at this time. All other functions of the equipment are operating normal.

Near Newhaven Dr, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival found flue pipe leaking water .i then cut the pipe and re do it .no leak at this monomer

Near Bayview Ct, Essex, MD 21221
Yonas M.

Yonas M.

Service call on 02/08/19 On arrival set unit to call for heat unit is not running checked electrical connections checked voltage and amps I call technical support if they know what is the problem I told them what I was checked on they told me reset the unit I did still the unit is not coming on if I found the problem they don’t have the parts for this unit no more. I highly recommended to replace the unit. About the payment Donna she collected.

Near Bayside Rd, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival cheked thermostats were calling for heat, then went to the roof to do maintenance on unit 1 and 2. We replace filters, change two belts, inspected heat exchanger, connections. We turn units back on and system is operating normal.

Near Middlesex Shopping Center, Essex, MD 21221
Christopher A.

Christopher A.

Upon arrival I went directly to the outdoor unit. Error code displayed 0 4- locked rotor. This is the same error code as before. Line voltage is 243. Capacitor is at full value. I reset the unit and it starts up. There must be a voltage drop causing the compressor amps to increase. I called Alex and installing a hard start kit will overcome any voltage issues to allow the compressor to start without faulting. Customer paid for adding a hard start. Discounted price reflects part cost and not labor.

Near Oakhurst Ave, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival found system not operating,found bad fan motor and weak cap ,also blower wheel is dirty .system not operating normal.customer couldn't afford repair .i tried to finance repair for him but he didn't get approved .

Near Middlesex Rd, Essex, MD 21221
Christopher A.

Christopher A.

I labeled the wires as I removed them from the board. I installed replacement board. No “high line voltage” or any other faults displayed. I had checked the other parts of the system the other day, including refrigerant pressures. Unit operating normal.

Near Oakhurst Ave, Essex, MD 21221
Christopher A.

Christopher A.

Outdoor units control board locked out and displaying the code for “locked rotor” or locked compressor rotor. I checked the wiring and capacitor and they were within specification. I reset the line voltage and control voltage to clear out the error from the board and tested the units operation. The compressor started operating and the unit was heating with normal refrigerant pressures and close to 30 degrees delta temperature indoors. I called tech support and they told me the only possible cause for this error is internal to the board. If the current sensing relay does not sense current it will cause this fault. The board needs to be replaced. I called Alex and let him know what the problem was and he okayed replacing th board.

Near Oakhurst Ave, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked caps,coil,safeties,heat exchanger.unit operating normal

Near Foxridge Ln, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked coil,blower,caps,safeties,unit operating normal

Near Foxcroft Ln, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked coil,caps,blower ,unit is couple months old ,system is operating normal

Near Arncliffe Rd, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival set unit to call for heat,checked system operation,checked exhaust system,blower,safeties replaced filter,found cracked heat exchanger,tagged system and turned the off .best to replace system ,customer has home warranty .

Near N Marlyn Ave, Essex, MD 21221
Daniel M.

Daniel M.

Removed old blower housing and motor . Installed new housing and set blower motor. Aligned blower pulleys and belt. Started and checked operations. Blower pulling 7.2 amps and rated for 9.6 amps . Supply air 133 and return air 75 . System is operating and costumer has heat

Near Middlesex Shopping Center, Essex, MD 21221
Youssef  D.

Youssef D.

Daniel didn't need me anymore

Near Middlesex Shopping Center, Essex, MD 21221
Daniel M.

Daniel M.

Replace blower assembly . Need to come back tomorrow when there is light

Near Middlesex Shopping Center, Essex, MD 21221
Youssef  D.

Youssef D.

On arrival found the back area unit have bad blower assembly,need to replace whole blower assembly .i turned system off until we replace parts.

Near Middlesex Shopping Center, Essex, MD 21221