Fall pm on 12/19/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain checked air filter checked blower motor checked compressor capacitor checked coil checked EWP and LWP also water temp also I sanded the flame rectification probe and checked burner arrangement the ignitor homes out to be in good condition checked all other electrical connections DT 45.2 unit made temp rise 30-60 unit tested unit operating normal at this time. Recommended duct cleaning uv lights installation and single or hole house surge protector needs to be installed to avoid future problems.

Near Longfellow Dr, Millersville, MD 21108
chrisa@supremeservicetoday.com

chrisa@supremeservicetoday.com

I checked the air filter. Customer needs to order a box of 28*30*2 filters. I checked the electrical wiring and electrical systems, including the auxiliary heat strips and all are within specification. I reset blower speeds to factory settings 2,5,7,10 from 2,7,9,10. This will blow warmer air from the unit. I operated the unit on second stage heating mode and recorded 25-30 degree temperature rise across the air coil. I set the flow rate to 3.5psi pressure drop so I could calculate heat of extraction and compare it to printed data. Heat of extraction is 28,000+ btu/hr which is better than printed data. Unit operating normal. Customer and I talked about a few accessories including a humidifier, surge protector and a WiFi thermostat for the geo unit. I sent estimates for all.

Near Tanager Dr, Millersville, MD 21108
nikolayn@supremeservicetoday.com

nikolayn@supremeservicetoday.com

Up on arrival made access panel to take manual damper out, patch access panel back up . Customer paid last time tech was here .

Near W Pasadena Rd, Millersville, MD 21108
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

On arrival set units to call for heat,measured supply and return air temp measured voltage and amps inspected electrical connections checked water pressure,coils,caps,Contactors,filters,drains,units are operating normal. Customer paid in full

Near W Pasadena Rd, Millersville, MD 21108
Christopher A.

Christopher A.

I pressurized the ground loop to 65psi. I vacuumed the EAC pre filters and reset the led panels. I checked the electrical wiring and electrical systems, including auxiliary heat strips, all are within specification except for the voltage absorption system for unit #1, which was replaced. I operated the units on second stage heating mode and recorded 25+ degrees delta temperatures across the air coil and normal heat of extraction. Both units are operating normal. Aprilaire #35 Water Panel

Near Rock Ridge Rd, Millersville, MD 21108
Marc M.

Marc M.

Found no issues with vent pipe. While there I gave options for a uv light install since there experiencing some impurities in the water still after there filtration system. Also gave a sales lead request form and a membership form. They were thinking of a geothermal unit installation. They also have a gas powered tankless water heater installed which is why I recommended our service agreement.

Near Hila Rd, Millersville, MD 21108
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters they are clean. units operating normal at this time. Also I gave customer three options that will benefit his geothermal system and service protection for the whole house

Near Vineland Ct, Millersville, MD 21108
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Up on arrival performed operational inspection, changed all filters and belts , checked all electrical components and parts, checked heat exchanger, checked all units for operation. All units working good at this time

Near Veterans Hwy, Millersville, MD 21108
Youssef  D.

Youssef D.

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked water pressure,capacitor,Contactor.unit operating normal

Near Millersville Rd, Millersville, MD 21108
ALEX K.

ALEX K.

Paying outstanding balance

Near W Pasadena Rd, Millersville, MD 21108
Yonas M.

Yonas M.

Service call08/26/19 On arrival customer explained to me what the inspector telling him the drain line needs to be inspected I set the unit unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain tested with water is working water is running out normal checked air filter checked outdoor condenser unit checked electrical connections checked compressor capacitor checked electrical connections checked voltage and amps measured pressure and temp measured subcooling and superheat unit operating normal at this time Collected $89 dispatch fee is kind of tuneup

Near Honeywood Ct, Millersville, MD 21108
Youssef  D.

Youssef D.

Up on arrival found high voltage wire from compressor to contractor is disconnected, connected new wire connection . Checked capacitor for micro Farads it was low , installed new capacitor, unit works normal

Near Tanager Dr, Millersville, MD 21108
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

On arrival preformed pm on units 4, 5, and 9. Units 5 and 9 are cooling properly with no concerns at the moment, all components working to spec. Unit #4, found low on charge, suction pressure very low and head pressure slightly low. Coil clean, filter clean, no other causes found. Recommend leak search and repair. Need to return to finish pm on units 6, 7, and 8.

Near Veterans Hwy, Millersville, MD 21108
Youssef  D.

Youssef D.

On arrival found system with clogged drain.cleaned it ,also added Algea tabs .tested drain .ok.also checked cube for ny faults .unit operating normal

Near Longfellow Dr, Millersville, MD 21108
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

On arrival inspected rtus 1-3. All systems are cooling efficiently and operating to spec. Attached pictures for details, no concerns at this time with units.

Near Veterans Hwy, Millersville, MD 21108
Youssef  D.

Youssef D.

On arrival found system operating but not cooling ,found unit air coil temp above freezing but not cooling (10 degrees delta ).added 1.5 lbs of 410a .which made delta t at 18 degrees .unit is operating normal at this time

Near W Pasadena Rd, Millersville, MD 21108
MarkM@supremeairllc.com

MarkM@supremeairllc.com

Replaced all the air filters. Started to check operations. Need to return to complete the maintenance.

Near Veterans Hwy, Millersville, MD 21108
Youssef  D.

Youssef D.

Upon arrival both systems cooling properly, downstairs unit operating normal and all components operating to spec. Upstairs unit operating with failed capacitor, recommended replacement and customer approved repairs. System now operating to spec.

Near W Pasadena Rd, Millersville, MD 21108
Youssef  D.

Youssef D.

On arrival set system to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned it ,checked coils ,caps.unit operating normal

Near Vineland Ct, Millersville, MD 21108
Yonas M.

Yonas M.

Spring Pm On 04/22/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter cleaned checked EWP and LWP also TEMP is good checked compressor capacitor all other electrical connections unit tested unit operating normal at this time.

Near Rock Ridge Rd, Millersville, MD 21108
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival checked thermostat was calling for cooling. Measured EWP,LWP,EWT,LWT, return temperature, supply temperature, amps, and voltage. Inspected electrical connections, blower wheel is clean,evaporator coil is clean, cleaned condensate drain line, and i replaced dirty filter provided by customer.

Near Severn Chapel Rd, Millersville, MD 21108
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival checked thermostat was calling for cooling. Measured EWT,LWT,EWP,LWP,return temperature 68.7 degrees, dupply temperature 46 degrees,amps, and voltage. Inspected electrical connections, contactor, capacitor rated for 40mfd, actual reading 39.6mfd, filter is clean, blower wheel is clean, and used a vacuum to clean condensate drain line. Unit is operating normal at this time.

Near Longfellow Dr, Millersville, MD 21108
ALEX K.

ALEX K.

Invoice created to clear up AR

Near Waterford Rd, Millersville, MD 21108
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival checked thermostat was calling for cooling. Measuredtemperature coming in and temperature going out, EWT,LWT,EWP,LWP. Measured amps, voltage, voltage absorption system. Inspected contactor, electrical connections, blower wheel is clean, evaporator coil is clean, replaced filter provided by customer. Unit needs to be pressurized. Customer stated that he is not ready yet to make a decision to become a member. Unit is operating normal at this time.

Near Brightview Ct, Millersville, MD 21108
Colin T.

Colin T.

Upon arrival I was told that multiple classrooms are hearing a very loud humming sound when Unit runs. Went to roof and system was running in ac mode. Could hear humming from inside classroom and right outside of unit. Opened up blower panel and found everything in tact and functioning normally. Belt used was AX48. Cannot use cogged (X) belts on Carrier Equipment. Per Carrier, it makes the belts wear faster and creates noise problems because their pulleys are designed for normal belts. Found spare A48 inside of another blower panel in a different unit. Replaced AX48 with A48 and ran fan only. Blower is quiet and not making any noise. Called for Ac and checked operation. Found no additional problems. Unit operating normally. **Next time we return we need to bring (2) A48 belts for spares. Customer also informed me that roofers have had to come out to patch the roof several times since we got the contract. She asked if we can be extremely careful when up there, not to drop any tools, par

Near Veterans Hwy, Millersville, MD 21108
Yonas M.

Yonas M.

Spring pm on 03/15/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced tested unit operating normal at this time. Also customer no more service for ductless heat pump just service the Geo water furnace.

Near Millersville Rd, Millersville, MD 21108
Christopher A.

Christopher A.

Unit had the red drain light flashing. I cleaned the condensate pan and drain lines and flushed out with hot water. I purged the air from the drain line and it drained properly. I confirmed proper flow rate and heat of rejection. I checked the electrical wiring and electrical systems, all are within specification. I increased low and high blower speeds by one but left the fan speed the same. Loop pressures are above 60 psi, so there was no need to pressurize the ground loop. Unit operating normal. Customer does not want estimates unless something is in need of repair.

Near Oakwood Rd, Millersville, MD 21108
Yonas M.

Yonas M.

Spring pm on 03/13/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked condenser unit checked electrical connections checked voltage and amps recommended duct cleaning also uv lights installation unit tested unit operating normal at this time.

Near Waterford Rd, Millersville, MD 21108
Yonas M.

Yonas M.

Fall pm on 02/26/29 On arrival set units to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters and replaced checked belts and replaced checked coils is cleaned units tested units operating normal at this time.

Near Veterans Hwy, Millersville, MD 21108
Colin T.

Colin T.

Upon arrival I went to system and shut off power. Removed old 3 wire damper actuator and replaced with new 2 wire actuator, both Honeywell. Mounted actuator to damper and tightened set screw. Labeled open and close on damper because you can’t see indicator very well. Returned power to system and ran heat. Checked operation of all dampers. Then called for zone 1 to be satisfied and actuator closed. Called for zone again and actuator opened. Then satisfied 2nd zone and 2nd floor actuator closed while both zone 1 actuators remained open. Satisfied system and dampers closed. Unit operating normal at this time.

Near Brightview Ct, Millersville, MD 21108
Colin T.

Colin T.

Replace Maxitrol pressure regulator on Carrier Unit (Cheetah Room). Upon arrival I went to roof and found system locked out on ignition fault, no gas, regulator stuck again. Shut off power and replaced gas regulator with new one. Removed vent tubing from old regulator and installed onto new one. Opened up gas valve and verified no leaks. Found normal incoming pressure so I returned power to system and ran heat until system satisfied thermostat. Went back down to thermostat and increased temp. Tested unit again and checked parameters until thermostat satisfied. Unit operating normal at this time.

Near Veterans Hwy, Millersville, MD 21108
Colin T.

Colin T.

Sent picture of economizer model to Matt.

Near Veterans Hwy, Millersville, MD 21108
Colin T.

Colin T.

Upon arrival I was told that heat in Cheetah room wasn’t working again and now the heat in Zebra room doesn’t seem to be working either. During diagnostics I found Cheetah room unit faulted on ignition lockout. Found no incoming gas to system. Maxitrol regulator stuck. Tapped on the bottom a few times until pressure released. Restarted system and ran heat. Checked all parameters and found no additional problems. Then went to Zebra room unit and found heat running but incoming air temp 50 degrees. Found economizer opened 100% because of failed outdoor temp sensor. Removed Economizer plug and put jumper plug on system to bypass Economizer. Tested heat and checked operation. Found no additional problems. Quoting customer to replace Maxitrol gas regulator and Economizer outdoor temp sensor.

Near Veterans Hwy, Millersville, MD 21108
Christopher A.

Christopher A.

Unit #9 on the second tier serves the classrooms. I found the unit would operate when the thermostat said “heat on” but the gas would turn off to th burners when the thermostat displayed “heat 2.” It is a single stage furnace but that should not have made a difference. However there was a black wire wired to the w2 terminal inside at the thermostat but no black wire used on the roof. I removed this wire from the w2 on the stat and jumped w1 and w2 together just to make sure w1 doesn’t drop voltage. Customer also had a concern about the blower noise. I assured them that this was unrelated but went back on the roof and tensioned the belt. It makes no aberrant noises. Unit operating normal.

Near Veterans Hwy, Millersville, MD 21108
Youssef  D.

Youssef D.

On arrival we found the cube water temperature coming in set to 30 degrees, we lower it 15 degrees and unit was operating normal.

Near W Pasadena Rd, Millersville, MD 21108
Daniel M.

Daniel M.

Checked operations on humidifier and wiring . Everything was working properly . When one zone would call both dampers would be open . Found in programming of thermostat that it wasn’t programmed for a 3 wire damper so it would drop out of voltage and open the damper back up after it dropped the call for heat . Changed the programming in stat and checked operations. After making adjustments I found that the round damper going to the addition is a three wire damper and now will not work with the changes . Called Alex and let him know . We need a 8” round 2 wire damper . For now I powered damper to be open all the time .

Near Brightview Ct, Millersville, MD 21108
Colin T.

Colin T.

Upon arrival I spoke with customer and confirmed that I wasn’t here to replace thermostat but to install Humidistat for humidifier operation. Went to unit and confirmed that series 3 cannot use humidity controlled communicating thermostat because it needs the AXB board. Customer already had daughter 24v board and geo was using ACC terminals to signal humidifier. Installed Humidistat onto return before Evap coil. Wired Humidistat to break R onlly when Blower is running for call for humidity. Tested and unit is operating normal. Office please send final email invoice after billing has been adjusted.

Near Brightview Ct, Millersville, MD 21108
Youssef  D.

Youssef D.

When we arrived we replaced motor but the new motor was defective ,went and got new motor ,tested it ,unit back on normal.

Near Waterford Rd, Millersville, MD 21108
Youssef  D.

Youssef D.

On arrival found indoor unit motor not operating ,need to replace motor .

Near Waterford Rd, Millersville, MD 21108
Daniel M.

Daniel M.

Replaced thermostat and checked operations . Found that the 3 series unit does not have the capability to have the humidifier work through the commucating thermostat . The humidifier needs a separate stat located on the duct work to be able to function .

Near Brightview Ct, Millersville, MD 21108
Daniel M.

Daniel M.

Unit that serves classroom 6 and 7 was making a humming noise. Found the belt was a little too tight . Readjusted pulley and checked system . System is operating properly

Near Veterans Hwy, Millersville, MD 21108
Daniel M.

Daniel M.

Completed heating maintenance on all systems .

Near Veterans Hwy, Millersville, MD 21108
Daniel M.

Daniel M.

Replaced filters on all RTUs . Need to come back to complete maintenance.

Near Veterans Hwy, Millersville, MD 21108
michaelr@supremeairllc.com

michaelr@supremeairllc.com

To replace sump pump with proflo .3 hp sump pump.... Replaced .3 hp sump pump with new proflo .3hp sump pump filled basin multiple times pump works properly

Near Aurora Dr, Millersville, MD 21108
Daniel M.

Daniel M.

Case #439629 . Spoke with Dave from waterfurnace and we confirmed that the master stat isn’t sending the call for humidity. Recommend replacing . Checked operations on humidifier and it is operating properly .

Near Brightview Ct, Millersville, MD 21108
Colin T.

Colin T.

Upon arrival I was told that 2nd classroom on left side of building first floor was blowing cold air and doesn’t have heat. Also, 2nd floor classroom on the left would intermittently blow cold air but system is satisfying. Found first floor classroom RTU wasn’t getting gas. Found maxitrol pressure regulator stuck or frozen. Tapped it a few times and gas released. Had manometer on system and checked pressure. Operating normal now but quoting to replace Maxitrol regulator. Then inspected 2nd floor system. Found unit operating normal but thermostat settings making unit blow cold air. Disabled fan with heat option, unit does this already and fan is being cycled too quickly during call for heat, blowing cold air at first. Then I found unit was programmed for adaptive recovery, causing unit to cycle on before schedule asks it to. Removed adaptation recovery. Tested unit and found it is operating normal.

Near Veterans Hwy, Millersville, MD 21108
Christopher A.

Christopher A.

I ran hot water with a prop shut off valve to the new humidifier. Replaced drain line with pvc. Tested unit for operation and for any water leaks. Humidifier is operating normal. Disregard remaining balance. Customer is paid in full.

Near Oakwood Rd, Millersville, MD 21108
Yonas M.

Yonas M.

Wayne water furnace fall preventative maintenance Crownsville Md

Near Severn Chapel Rd, Millersville, MD 21108
Millersville, MD - Wayne water furnace fall preventative maintenance Crownsville Md
Yonas M.

Yonas M.

Fall pm Wayne water furnace rock ridge rd Millersville Md

Near Rock Ridge Rd, Millersville, MD 21108
Millersville, MD - Fall pm Wayne water furnace rock ridge rd Millersville Md
Daniel M.

Daniel M.

Maintenance on a Water Furnace system in Millersville , MD .

Near Millersville Rd, Millersville, MD 21108
Millersville, MD - Maintenance on a Water Furnace system in Millersville , MD .