Mount Airy, MD Air Conditioning, Heating and Plumbing Services

Supreme Service Today provides Air Conditioning, Heating and Plumbing Services, Repair, Installation, Maintenance, and Tune Up in Mount Airy, MD and surrounding areas.

Check out what some of our customers are saying about Supreme Service Today.

Local Reviews
for Mount Airy, MD

Supreme Service Today Rated 5.0 out of 5 stars based on 2 customer reviews

Map of Mount Airy, MD

Great




Review of Supreme Service Today

Marc was a real professional. He took the time to answer my dumb questions and I feel great about the entire experience. Look forward to getting my jobs completed


Map of Mount Airy, MD

Chris did a great job!




Review of Supreme Service Today

I really appreciated that chris called ahead, was on time, and found a problem other technicians overlooked.


marcm@supremeservicetoday.com

marcm@supremeservicetoday.com

Install laundry tub in Replace kitchen faucet, replace hose bib. And install utility sink for basement. Tested no leaks good to go.

Near Buffalo Rd, Mount Airy, MD 21771
marcm@supremeservicetoday.com

marcm@supremeservicetoday.com

Replace kitchen faucet, replace hose bib. And install utility sink for basement. Tested no leaks good to go.

Near Buffalo Rd, Mount Airy, MD 21771
marcm@supremeservicetoday.com

marcm@supremeservicetoday.com

Will return once all items have been delivered to home to be installed. Collected 478.50 for the deposit for work. Will collect the remaining 478.50 when we come back to install everything.

Near Buffalo Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

Return visit on 01/13/20 On arrival turn off the unit from disconnect box take the old INTELLIZONE2 out unwired the low voltage wires put the new INTELLIZONE2 in rewire the low voltage wires checked electrical connections checked voltage and amps start up all zoning dumpers is open and closing normal measured supply and return air temp checked all other electrical connections unit operating normal at this time. No payment collected is full paid.

Near Braddock Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

Return visit on 01/06/20 On arrival turn the unit off from disconnect box an wired low voltage wires from zoning dampers take out all 4 of them installed new Honeywell zoning dampers tested checked electrical connections checked voltage and amps I found zone #3 no low voltage checked the tell zone bord no 24v for zone #3 I take out the wires for zone 3 I put on zone #4 I have 24v from tell zone also in zoning dampers but is not open or closed from the thermostat I call water furnace tech support they told me tell zone board is bad I have to replace the tell zone board I gave quote for customer also customer gate special discount by Alex customer accepted the quote I ordered the parts we have to come back to install tell zone. Collected $1030 for zoning dampers installation full amount of and $285.00 for tell zone repair full amount total $1315.00on C.C we have to come back to replace the tell zone unit operating normal at this time. TELL ZONE REPLACEMENT

Near Braddock Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

Fall pm on 12/23/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain checked air filter and replaced checked compressor capacitor checked EWP and LWP checked water temp checked blower motor checked coil checked all other electrical connections also customer has problems with zoning damper I tested 3 damper they’re gat 24v but is not open or closed I suggested to replacing now to avoid future problems I gave quote for customer also customer has special discount by ,Alex customer accepted the quote i order the parts we have to come back to install it unit tested unit operating normal at. Recommended duct cleaning also wet switch and tell start installation to avoid future problems.no payment Collected at this time customer he will pay the total payment after the job is done. HONEYWELL DAMPERS REPLACEMENT QTY. 4

Near Braddock Rd, Mount Airy, MD 21771
colint@supremeservicetoday.com

colint@supremeservicetoday.com

Replaced variable speed pump for top floor geo. Added into low flow center until all air was removed from system and pressure rose to spec. Tested operation of geo system as well. Unit operating normal. Inspected operation of basement geo as well to verify specs.

Near Heavenly Cause Ct, Mount Airy, MD 21771
colint@supremeservicetoday.com

colint@supremeservicetoday.com

Upon arrival I found low flow center leaking at cap, reservoir too full from pressurizing top floor system. Put flush cart adapter on flow center and drained reservoir until it stopped leaking then opened up flow center to verified water isn’t leaking out of the cap anymore. Customer still has issue with E16 on top floor system. Found variable speed pump getting 240v but only pulling .2 amps, rated for 1.7. Removed dc wires to see if pump would run at 100% and it didn’t. VS pump is bad, which is on the supply side of flow center, which is why we were seeing a negative water pressure (water being pushed out to loop but not going up to unit). Low Flow Center is in the basement while the unit is on the top floor. Spoke to customer about repair and he would like to talk to Alex about Low Flow Center and Pump moving forward. We may want to move low flow upstairs so it doesn’t fight gravity so much.

Near Heavenly Cause Ct, Mount Airy, MD 21771
Yonas M.

Yonas M.

Fall pm on 12/12/19 On arrival set units to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain checked air filter checked blower motor checked coil checked EWP and LWP I found unit #2 the thermostat is gave me E16 codes EWP and LWP is 0psi Check water temp it was 5 degrees DT checked voltage and amps I have 2.09 amps for the pump pump is running fine unplug the power to the pump no psi deference still 0 psi when I plug the wires back to the pump still 0 psi also I was pump the loop for 5 psi water to it water was overflow from the low flow sensor on this point I called water furnace tech support tell the what I see they’re told me to move the flow sensor next to the unit or that E16 codes is comes back to the thermostat I rescheduled the customer for tomorrow to more diagnostic to the unit what we can do about it both unit operating normal at this time unit #2 has E16 error codes on the thermostat.

Near Heavenly Cause Ct, Mount Airy, MD 21771
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

I replaced the filter with one provided by the customer. I checked the electrical wiring and electrical systems including the auxiliary heat strips, all are within specification. I operated the unit on second stage heating mode and recorded actual heat of extraction of 37,000+ btu/hr. I recorded 30+ degree temperature rise across the air coil. I pressurized the ground loop to 65psi. Unit operating normal.

Near Merrifield Ct, Mount Airy, MD 21771
Youssef  D.

Youssef D.

On arrival installed 2 eztraps ans one wet switch.also replaced flame sensor on the first floor unit.tested units operations .units operating normal

Near Kings Forest Trail, Mount Airy, MD 21771
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Up on arrival performed fall maintenance. Tested 2 thermostat, tested 2 units for operation, found poor flame sensor on unit on ground level, recommended to replace flame sensor, also recommended to install wet switch and ez trap on upper system, and ez trap on the lower system. All systems operating normal at this time .

Near Kings Forest Trail, Mount Airy, MD 21771
Christopher A.

Christopher A.

I replaced the air filter in the attic with one provided by the customer. The one for downstairs was fine. I checked the electrical wiring and electrical systems, all are within specification including the auxiliary heat strips and overheat safety devices. I pressurized the ground loop to 65psi, confirmed proper flow rate and heat of extraction. Both units have normal temperature rise in second stage heating mode. Customer wanted hot water generator turned off. Both units are operating normal. I noticed no form of electrical surge protection and recommended adding whole house surge protectors and Intellistart Modules for each geo unit.

Near Nathaniel Dr, Mount Airy, MD 21771
Christopher A.

Christopher A.

I cleaned the evaporator coil and flushed with battery powered pressure washer. I sealed up filter access that is not being used. Coil is like brand new. Customer paid in full.

Near Detrick Rd, Mount Airy, MD 21771
Christopher A.

Christopher A.

I replaced the Air Knight PX5 UV bulb and checked for proper operation. Customer paid in full.

Near Detrick Rd, Mount Airy, MD 21771
Youssef  D.

Youssef D.

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections inspected water pressure and raised it ,checked electric heat .found dirty evaporator coil and blown uv light bulb .customer paid in full for evaporator coil cleaning and uv bulb replacement . Unit is operating normal at this time.

Near Detrick Rd, Mount Airy, MD 21771
Colin T.

Colin T.

Upon arrival I removed all refrigerant from system, 140oz. Removed filter drier and txv. Installed new txv and filter drier. Pressurized with nitrogen to 400psi, no leaks. Removed nitrogen and vacuumed system down to 500micron. Replaced control board while unit was vacuuming. Added factory charge of 140oz. Returned power to system and tested ac using zone panel. Called for ac about 10 times and system cycled on normally every time. Called for ac from thermostat and checked operation. Unit operating normal. Customer said he has been hearing whooshing sound for attic system. Capacitors in spec and refrigerant charge normal. Customer doesn’t have oil trap, need to confirm with office about needed an oil trap or not to stop excessive noise. Finally customer said he is interested in installing buffer tank and Dhw pipes for supplemental water heating. He would like a call from office about this.

Near Penn Shop Rd, Mount Airy, MD 21771
Colin T.

Colin T.

Upon arrival customer called for ac on both zones but system didn’t cycle on right away, Y1 and Y2 present at Board, no faults or error codes, but no voltage at CC or CCHI. Reset system and let unit naturally come on, when system came on it sounded like a lot of air pressure in ducts. Found zone 2 damper wasn’t opening when called, getting stuck. Had to remove actuator from damper, clean shaft and reattach set screw. Tested damper multiple times. Then put gauges on system because I found low delta air temp at evap coil. Compared refrigerant pressures to installation manual with 70 degree water temp, low suction pressure, high discharge pressure, high Superheat, high subcool, low delta air temp at Evap coil. Restricted txv, previous quote has been uploaded already. System satisfied thermostat during visit but discharge pressure was slowly rising. Let unit cycle on again but compressor didn’t come on until after 10 minutes of waiting. The call for compressor is being lost in the co

Near Penn Shop Rd, Mount Airy, MD 21771
Youssef  D.

Youssef D.

On arrival noticed system keeps cutting off every time system goes to second stage .called tech support and advised me to rewire cc and cclo on the board ,then unit started operating normal but noticed the pressure is not where It suppose and slowly started to go up .i recommended replacing Txv .unit is operating normal at this time. Darlene is contacting customer for billing and creating an invoice

Near Penn Shop Rd, Mount Airy, MD 21771
Youssef  D.

Youssef D.

On arrival replaced circuit board per work order .unit short cycled again .need to come back during normal operation hours to speak to water funace .unit is not operating normal

Near Penn Shop Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

Service call 07/01/19 on arrival set unit to call for cooling no error code or any fault measured supply and return air temp measured voltage and amps inspected electrical connections checked filter is cleaned checked compressor capacitor checked pressure and they are ideal indicating zero leaks checked EWP and LWP I found the compressor is short cycling running for 5 minutes and shut off I called water furnace tech support I checked some steps with the we found out the board is bad I explained the customer I gave quote he accepted I ordered the board we have to come back to finish the job also customer has problems with the dumpers we changed 1 month ago but still customer have the same problem after we change the board we have to check the zoning board and the dumpers. Collected $350 for job deposit on CC on file and I have case number and part number for board Case#498003 Part #17p513-01

Near Penn Shop Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

Spring Pm On 06/27/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked EWP and LWP also temp checked all other electrical connections tested unit operating normal at this time.

Near Mullinix Mill Rd, Mount Airy, MD 21771
Youssef  D.

Youssef D.

Upon arrival replaced failing capacitor, tested system operation normal.

Near Nathaniel Dr, Mount Airy, MD 21771
Youssef  D.

Youssef D.

Upon arrival both systems cooling properly, temps and pressures in acceptable ranges. Run capacitor for downstairs unit below allowable variance, recommend replacing. Customer agreed to replace, tech does not have part on truck, office must contact customer to reschedule follow up visit. Customer prefers any day but Monday, anytime after noon. Customer will pay balance for replacement upon completion of work.

Near Nathaniel Dr, Mount Airy, MD 21771
Christopher A.

Christopher A.

Outstanding balance 16.66

Near Nathaniel Dr, Mount Airy, MD 21771
Youssef  D.

Youssef D.

On arrival found zone 1 not opening ,found yellow not connected all the way in the zone board terminal ,connected it ,zone 1 responded ,unit operating at this time

Near Penn Shop Rd, Mount Airy, MD 21771
Youssef  D.

Youssef D.

Invoice created to clear up AR

Near Braddock Rd, Mount Airy, MD 21771
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival checked thermostat was calling for cooling. Measured EWP,LWP,EWT,LWT,return, supply, amps, and voltage. Inspected electrical connections, capacitor, contactor, blower wheel is clean, evaporator coil is clean, replaced filter provided by customer, tested condensate pump, clean condensate drain line, and also pressurized it to 60psi.

Near Braddock Rd, Mount Airy, MD 21771
Youssef  D.

Youssef D.

On arrival removed old dampers and I installed (2) - 12x26 dampers (motor on 12" side) Honeywell damper.tested them ,Botha's dampers are responding normal

Near Penn Shop Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

Spring pm on 03/26/29 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked water I found humidity problem in house recommended to install dehumidifier I gave quote for customer he needs some time to talk his wife and his going to call us unit tested unit operating normal at this time.

Near Detrick Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

GEO water furnace spring Pm Mount Airy Md

Near Detrick Rd, Mount Airy, MD 21771
Mount Airy, MD - GEO water furnace spring Pm Mount Airy Md
Yonas M.

Yonas M.

GEO water furnace spring Pm on Mount Airy Md

Near Detrick Rd, Mount Airy, MD 21771
Mount Airy, MD - GEO water furnace spring Pm on Mount Airy Md
Christopher A.

Christopher A.

Estimate for Honeywell zone panel, 2-Water Furnace Intelli Starts. I started by installing the 2 Intellistart modules. The large one went in the package unit and the smaller one went into the cube. I tested by units operation to ensure start up of the compressors. Next I wrote down the configuration of the zone panel before removing power and the wires. I then installed new zone board and set to previous configuration. I tested the operation through the zone board. Customer came down and confirmed proper operation and damper positions.

Near Penn Shop Rd, Mount Airy, MD 21771
Christopher A.

Christopher A.

While hanging crown molding yesterday customer inadvertently put a trim nail through the Tstat wire bundle. The wire was inaccessible to get to it and splice. The best option was to run the wire to a wall in the kitchen. Customer and I ran 15 ft of wire and I wired the Tstat and unit back together. I tested the unit with the aid tool and the unit is operating normal.

Near Heavenly Cause Ct, Mount Airy, MD 21771
ALEX K.

ALEX K.

Estimate for Honeywell zone panel, 2-Water Furnace Intelli Starts, 1 -zone damper ( for zone 2 of the 1st Floor)

Near Penn Shop Rd, Mount Airy, MD 21771
Youssef  D.

Youssef D.

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked water pressure,cap,contactor ,coils,replaced cap.unit operating normal

Near Merrifield Ct, Mount Airy, MD 21771
Christopher A.

Christopher A.

Fall pm on arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters recommended for unit #1 capacitor need to be replaced I gave quote for customer customer accepted I ordered we have to come back to finish the job also customer have issues with unit #1 unit running non stop and the damper is closing still unit running. Another technician come out to find the problem collected $127 for capacitor replacement. No balance left for this job. I replaced the run capacitor. I tested zone dampers from the zone board and they open and close normal. Customer will video tape any future occurrence. Customer asked for an estimate to install Intellistart Module. I prepared a quote and verbally gave them the cost and will email it as well.

Near Penn Shop Rd, Mount Airy, MD 21771
Yonas M.

Yonas M.

Fall pm on arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters recommended for unit #1 capacitor need to be replaced I gave quote for customer customer accepted I ordered we have to come back to finish the job also customer have issues with unit #1 unit running non stop and the damper is closing still unit running. Another technician come out to find the problem collected $127 for capacitor replacement. No balance left for this job

Near Penn Shop Rd, Mount Airy, MD 21771
Christopher A.

Christopher A.

I replaced the air filter with one provided by the customer. I found the pressure drop and heat of extraction to be lower than printed data for this unit. The axb setup was at 50 and 100 vs pump which allows for maximum flow through the pump. There was no valve on the loop piping so I went to the pumps and the vs pump was warm and working but the other pump was cold and clearly not working. I found no voltage at the pump and traced it to inside the unit. I wired it into the fixed pump relay p1 and p2 and started the unit. Pump drawing .98 amps and the pressure drop actually needed to be slowed down slightly with both pumps working. I set flow rate correctly. Loop pressure was good. I checked the electrical wiring and electrical systems, all are within specification. Unit operating normal.

Near Mullinix Mill Rd, Mount Airy, MD 21771
Colin T.

Colin T.

Called customer and he informed me that nobody would be home during service. During diagnostics I found no LED lights at boiler or zone panel. Checked voltage and found none at boiler. Got access to basement of house per customer and I found 20amp breaker tripped. Reset and tested unit operation. Also labeled breaker. Found 10amps total ONLY when boiler is firing up. During normal operation I found unit was pulling 6.5amps total. Checked operation of pumps, boiler, stat, and zone control. Amp draw readings taken were from main power at breaker reading all motor amperages. Found P/T sight glass on boiler is full with water and difficult to read. Continued to run system and found no additional problems. Suggest 20amp breaker get replaced, possibly weak and prematurely tripping. Left system running to make sure Desert Aire System satisfies and customer sees that it is working. Locked basement door and front pool door. Left back pool door unlocked. Office please follow up with customer. N

Near Chelsea Cir, Mount Airy, MD 21771
Daniel M.

Daniel M.

Replacing indoor fan motor on Water furnace Air handler in Mt. Airy , MD .

Near Nathaniel Dr, Mount Airy, MD 21771
Mount Airy, MD - Replacing indoor fan motor on Water furnace Air handler in Mt. Airy , MD .
Yonas M.

Yonas M.

Wayne water furnace service taylorsville Md

Near Braddock Rd, Mount Airy, MD 21771
Mount Airy, MD - Wayne water furnace service taylorsville Md
Daniel M.

Daniel M.

Maintenance on a Carrier air handler in Monkton, MD

Near Runkles Rd, Mount Airy, MD 21771
Mount Airy, MD - Maintenance on a Carrier air handler in Monkton, MD