Odenton, MD Air Conditioning, Heating and Plumbing Services

Supreme Service Today provides Air Conditioning, Heating and Plumbing Services, Repair, Installation, Maintenance, and Tune Up in Odenton, MD and surrounding areas.

Check out what some of our customers are saying about Supreme Service Today.

Local Reviews
for Odenton, MD

Supreme Service Today Rated 4.2 out of 5 stars based on 5 customer reviews

Map of Odenton, MD

Great service




Review of Supreme Service Today

West was extremely informative and provided great service. It was a very educational experience.


Map of Odenton, MD

Wasn’t impressed




Review of Supreme Service Today


Map of Odenton, MD

Great service




Review of Supreme Service Today

A little late but great service


Map of Odenton, MD

ac check




Review of Supreme Service Today

excellent


Map of Odenton, MD

Great service




Review of Supreme Service Today


Yonas M.

Yonas M.

Service call on 01/13/20 On arrival customer explained to me what happened this morning unit set point 68 but the house temp 77 unit is running I set the unit for heat measured supply and return air temp measured voltage and amps checked unit contactor checked electrical connections no error codes when I put my aurora I call water furnace tech support I was explained the technician he was telling me to reset the thermostat reprogramming the thermostat unit start operating normal i set unit to call for heat unit shut off on set point but I suggested to replacing the thermostat to avoid future problems I gave quote for customer accepted I ordered the water furnace thermostat we have to come back to replace the thermostat also customer sign new service agreement with us Collected $626.45 full amount of the job on C.C on file unit operating normal at this time.

Near Brink Ct, Odenton, MD 21113
Daniel S.

Daniel S.

Heat limit thermostat. Tested system found unit heat limit thermostat to be stuck open and need replacement. Replaced limit and tested system now operating properly. Spoke with customer about unit being old and up they set up a free comfort consultation to see if the want to install a new unit.

Near Capistrano Way, Odenton, MD 21113
nikolayn@supremeservicetoday.com

nikolayn@supremeservicetoday.com

Up on arrival for not heating properly didn’t find anything. Unit operating normal. Customer payed by check.

Near Capistrano Way, Odenton, MD 21113
marcm@supremeservicetoday.com

marcm@supremeservicetoday.com

Replace wax ring on toilet in upstairs bathroom. Upon arrival found flange to be set right when they replaced the floor. Tested no leaks and secured to floor.

Near Miles River Ct, Odenton, MD 21113
marcm@supremeservicetoday.com

marcm@supremeservicetoday.com

Gave estimates for replacing and repairing toilets. Also found issues that are urgent for water heater.

Near Scaffold Way, Odenton, MD 21113
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Replace wax ring on toilet. Replace flange. Flange was rusted out completely. Sub floor is also damaged around flange will need to have customer fix floor before I can repair the flange and reinstall the toilet. If I installed now toilet would rock and but loose and no way to tie them down wood is to rotted away from water damage from no wax ring present. Replace garbage disposal. We need to schedule return to complete this work.

Near Miles River Ct, Odenton, MD 21113
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Cut into ceiling and find where leak is coming from.will also tarp the room down so debri doesn’t get everywhere. Will then give actual estimate for repairs once I cut into ceiling. Were not responsible for replacing dry wall. Will give a recommendation for repair of dry wall. Collected deposit of 100.00 for work to be completed Friday.

Near Miles River Ct, Odenton, MD 21113
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Upon arrival found garbage disposal in the locked up mode. Turns on but no motor function to turn the blades which means the motor has locked up and needs to be replaced. After replacement I tested functionality and works how it should.

Near Trout Run Ct, Odenton, MD 21113
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Up on arrival performed fall maintenance on 11/05/2019. Tested thermostat for operation, tested unit for operation. Took delta T . Took readings of all electrical components. Air filter ( 16x25x1 ) was just Replaced couple days ago. Unit working good at this time.

Near Capistrano Way, Odenton, MD 21113
Colin T.

Colin T.

Arrived to complete fall preventative maintenance. Verified system proper operations in heat test mode. Found unit 2 is starting to rust and there is a large potential of heat exchanger cracking. Did not find crack but rust is building on all tubes. With this and high heat rise temps we are quoting that the heat exchanger get replaced before heating season starts. Parts waiting quote for repair.

Near Becknel Ave, Odenton, MD 21113
Christopher A.

Christopher A.

I replaced the air filter with one provided by the customer. I checked the electrical wiring and electrical systems, all are within specification but the cold igniter had a high resistance. It was ultimately replaced with a Silicone Nitride hot surface igniter. The inducer motor was pulling under rated amperage which is a good thing. I set gas pressure to just <=3.5iwc. I checked temperature rise which is normal. Heat exchanger exhibits no breaches and there is no flame roll out at ignition. Gas furnace is operating normal.

Near Autumn Ridge Ct, Odenton, MD 21113
Marc M.

Marc M.

Change out s-trap and install proper p trap. Installed proper p-trap and drains with no leaks. Customer was very happy with job. Will call us again for future repairs. Waived dispatch fee for approval of repairs.

Near Junco Ct, Odenton, MD 21113
Marc M.

Marc M.

Replaced water heater tied onto existing connections no leaks tested and lite pilot.

Near Capistrano Way, Odenton, MD 21113
Marc M.

Marc M.

Replace leaking water heater 50 gl gas atmospheric vent with a 40 gl gas atmospheric w/ pan and expansion tank. Will need to shut down water to swap the out the gate valve and install ball valve.

Near Capistrano Way, Odenton, MD 21113
Yonas M.

Yonas M.

PRESSURE NITROGEN CLEANING UP TESTED Service call on 08/26/19 On arrival open the Evaporator coil cabinet is full of water checked the drain line is clogged vacuum the water and tested still the water backup I gave quote for customer to pressure drain line with nitrogen and cleaned up customer accepted the quote pressure nitrogen to the drain line cleaned up cleaned the Evaporator coil pan vacuum the drain tested put water to the pan water is running out normal checked electrical connections checked voltage and amps checked measured supply and return air temp checked condenser unit checked compressor capacitor measured pressure and temp checked superheat and subcooling unit operating normal at this time Collected $283 for drain line cleaning and $89 dispatch fee total &372.00 On C.C on file

Near Astilbe Way, Odenton, MD 21113
Yonas M.

Yonas M.

Service call 08/26/19 on arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain checked air filter cleaned checked outdoor condenser unit checked electrical connections checked voltage and amps measured pressure and temp also measured superheat and subcooling I found the unit low on charge I put 3 oz to make sure the metering device is working the metering device is good I gave quote for customer to electrical like search also recharge the unit with 2 pound 410a customer she don’t approve the quote she needs time to decide what she wants to do unit is running but is low on charge. Collected $89 dispatch fee and $124 for diagnostic fee total $213 on C.C on file

Near Canteen Cir, Odenton, MD 21113
Yonas M.

Yonas M.

Service call 07/16/19 on arrival set unit to call for cooling nothing is running I was checked the furnace the door is open customer explained to me he changed the air filter and the unit is not running I checked electrical connections checked voltage and amps checked blower motor and blower capacitor put back the furnace door back set unit for cooling measured supply and return air temp I have 20 degrees DT checked condenser unit outdoor checked pressure and temp and they’re ideal indicating zero leaks checked compressor capacitor checked coil and all other electrical connections in unit tested unit operating normal at this time. Collected $89 dispatch fee and $124 diagnostic fee total $213 on C.C also highly recommended duct cleaning I gave quote for customer he is going to call us back when he is ready.

Near Meadow Wood Ct, Odenton, MD 21113
Youssef  D.

Youssef D.

Completed the A/C tune up. Checked wiring and connections. Checked the drain line and trap. Checked the unit and thermostat operation. Found during the preventive maintenance that there is a supply duct that feeds back to the return duct. Also found a vent which I believe is a outside air supply but can’t get to the line from inside. House is humid and the customer has to run 2 dehumidifiers.

Near Sunny Ridge Dr, Odenton, MD 21113
Yonas M.

Yonas M.

Tuneup special on 05/31/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked condenser unit checked electrical connections checked voltage and amps checked compressor capacitor checked all other electrical connections recommended replaced compressor contractor unit tested unit operating normal at this time also customer sign new service agreement collected $16.66 for one month SA fee on C.C.

Near Capistrano Way, Odenton, MD 21113
Yonas M.

Yonas M.

Spring Pm on 05/29/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked condenser coil checked electrical connections checked voltage and amps checked compressor capacitor checked coil unit operating normal at this time.

Near Iron Corner Ct, Odenton, MD 21113
Yonas M.

Yonas M.

Spring Pm On 05/14/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter checked condenser coil outdoor checked compressor capacitor checked voltage and amps checked all other electrical connections unit tested unit operating normal at this time.recommended blower motor capacitor needs to be replaced also blower wheel needs to be cleaned.

Near Holiday St, Odenton, MD 21113
Youssef  D.

Youssef D.

On arrival found system leaking of the filter drier .replaced the filter drier .checked for leaks ,vacuumed system to 500 microns.recharged system with 8lbs of 410a ,system operating normal .

Near Holiday St, Odenton, MD 21113
Colin T.

Colin T.

Upon arrival I was shown leaking cpvc pipe. Shut off water and drained pipe. Cut back from coupling to Tee. Replaced coupling, used new pipe to connect to Tee. Used bushing reducer to connect to washing machine pipe. Used primer and glue to seal tight. Once connected I turned water back on and found no leaks. After speaking with customer they would also like to get a quote to fix a clog they have in both upstairs bathrooms but would like to speak with supervisor about previous work before approving another repair. Also customer asked if we knew of a carpet cleaning company, asked Alex to give them contact when he reaches out.

Near Miles River Ct, Odenton, MD 21113
Yonas M.

Yonas M.

The job is not finish we need some cpvc glow I don’t have customer he needs to go work we have to come back finish the job tomorrow 10am customer he will be home.

Near Miles River Ct, Odenton, MD 21113
michaelr@supremeairllc.com

michaelr@supremeairllc.com

leak in wall leak is coming from a water line between two floors recommend cut into wall 1st and 2nd floor of the house replace water lines and tie in

Near Bright Meadow Ct, Odenton, MD 21113
Yonas M.

Yonas M.

On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked condenser unit checked pressure checked refrigerant i found low refrigerant 48 psi and R22 riding 27 not obviously like also the run capacitor is low riding I gave quote for customer customer accepted just to charge the refrigerant customer he have planned to replace the hole unit I charge 1.13 pounds of refrigerant R22 unit tested unit operating normal at this time. Recommended to replace the run capacitor for condenser unit also duct needs to be cleaned. Collected $515 for add refrigerant R22 1.13 pound also $59 for tune Up total $574 on C.C

Near Trout Run Ct, Odenton, MD 21113
Yonas M.

Yonas M.

Bryant condenser unit tune Up Odenton Md

Near Trout Run Ct, Odenton, MD 21113
Odenton, MD - Bryant condenser unit tune Up Odenton Md
Daniel M.

Daniel M.

Completed AC maintenance

Near Becknel Ave, Odenton, MD 21113
Derrick S.

Derrick S.

To replace 40 gallon gas water heater with atmospheric vent , will need to bring heater through house no basement door access , will need to install expansion tank and pan as well

Near Miles River Ct, Odenton, MD 21113
Colin T.

Colin T.

Upon arrival I was told that furnace was working but inspector asked them to have furnace looked at to address a few items. Went to furnace and ran heat. Inspector mentioned a yellow flame but I do not see that. Flame is blue with small trails of orange deep inside of heat exchanger which is normal. I did find gas pressure slightly high, 3.75inches, lowered to spec at 3.5inches. Also found a good amount of air bleeding from small gaps in unit. Used tape to seal air gaps. Continued to run furnace and found heat rise of 43, normal. Filter is clean, blower and coil are clean. Unit is pretty new and is operating normal at this time.

Near Militia Pl, Odenton, MD 21113
Youssef  D.

Youssef D.

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked coils,blower ,cap,contractor .unit operating normal

Near Canteen Cir, Odenton, MD 21113
Daniel M.

Daniel M.

Upon arrival I found furnace off. Turned on to find inducer motor not running, only humming. Capacitor in spec and motor getting correct voltage. Quoted customer to replace inducer Assembly and he approved and paid half. Office please contact customer with update on part and to schedule return. 12-7-18 (DM) replaced inducer motor assembly and checked operations . Adjusted fan speed to get unit into specs. System is operating but poorly. The system makes a lot of noise from blower motor but everything is tight and in-line with amps . Unit is 23 years old so I informed the costumer about the noise and the life expectancy of the furnace . Supply air 131 degrees and return air 80 degrees .

Near Fall Ridge Way, Odenton, MD 21054
Colin T.

Colin T.

Upon arrival I found furnace off. Turned on to find inducer motor not running, only humming. Capacitor in spec and motor getting correct voltage. Quoted customer to replace inducer Assembly and he approved and paid half. Office please contact customer with update on part and to schedule return.

Near Fall Ridge Way, Odenton, MD 21054
Colin T.

Colin T.

Called customer at 740, no answer, left vm. Called again at 750 and no answer. Waited another 15 mins and no call back.

Near Fall Ridge Way, Odenton, MD 21054
Yonas M.

Yonas M.

Trane unit fun motor burnt out odenton Md

Near Meadow Wood Ct, Odenton, MD 21113
Odenton, MD - Trane unit fun motor burnt out  odenton Md
Christopher A.

Christopher A.

Commercial maintenance on Goodman units in Odenton, MD.

Near Becknel Ave, Odenton, MD 21113
Odenton, MD - Commercial maintenance on Goodman units in Odenton, MD.
Yonas M.

Yonas M.

Carrier unit service tune Up

Near Iron Corner Ct, Odenton, MD 21113
Odenton, MD - Carrier unit service tune Up