Pasadena, MD Air Conditioning, Heating and Plumbing Services

Supreme Service Today provides Air Conditioning, Heating and Plumbing Services, Repair, Installation, Maintenance, and Tune Up in Pasadena, MD and surrounding areas.

Check out what some of our customers are saying about Supreme Service Today.

Local Reviews
for Pasadena, MD

Supreme Service Today Rated 4.0 out of 5 stars based on 4 customer reviews

Map of Pasadena, MD

Poor No longer wish to be a customer




Review of Supreme Service Today

I spoke to Shelton Cartwright from Water Furnace. My neighbor is getting a Water Furnace geothermal system in his new house from Bay Heating and Cooling in Annapolis. We will use them for our future service needs. Alex refused my phone calls about the problems we have been experiencing about not coming to our home for prescheduled appointments. Go to hell!!!


Map of Pasadena, MD

Job done on time and for the price agreed to.




Review of Supreme Service Today

Each employee that we dealt with was courteous and they knew their job. The clean up was thorough.


Map of Pasadena, MD

I heard the vacuum and rattle of actual maintenance being performed. for once.




Review of Supreme Service Today

He serviced the unit and explained I needed my ducts cleaned. very professional.


Map of Pasadena, MD

Great service tech. Real gentleman.




Review of Supreme Service Today

Excellent


Daniel S.

Daniel S.

Inspected system found drain cap to be missing. Replaced drain cap and cleaned drain line. Unit running properly.

Near Dorshire Ct, Pasadena, MD 21122
Yonas M.

Yonas M.

Fall pm on 01/15/20 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain checked air filter cleaned checked compressor capacitor checked coil checked blower motor checked EWP and LWP it was low I pump it back up to 69/69 psi checked water temp also customer has problems with zoning dampers the one we installed 1 of the zoning dampers is connected with zone 2 thermostat customer she wont to move zone 1 thermostat I move the wires to zone 1 and rewire the low voltage wires and make it work unit tested unit operating normal at this time. Recommended duct cleaning Uv lights installation and Ez trap or wet switch installation to avoid future problems.

Near Royal Beach Rd, Pasadena, MD 21122
colint@supremeservicetoday.com

colint@supremeservicetoday.com

Upon arrival I was told that cash office in back is still cold. Found thermostat located in workshop area, satisfied at 68. Went to office and found temperature is 64. Do not suggest moving temp sensor to office area because that will make workshop way too hot. Since workshop has 4 registers and each office adjacent has only 1 per office I’m suggesting we install damper diffusers in registers to balance airflow. These registers do not have the clips for damper diffusers so I’m quoting customer to replace ceiling registers with new so we can add dampers to each. Nothing I can do to fix today.

Near Ritchie Hwy, Pasadena, MD 21122
Daniel S.

Daniel S.

Replaced bad controls board unit and tested unit now heating

Near Ritchie Hwy, Pasadena, MD 21122
youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com

Helped installers finishing a new install job

Near Poplar Ridge Rd, Pasadena, MD 21122
chrisa@supremeservicetoday.com

chrisa@supremeservicetoday.com

I checked the zone board and zone dampers because customer had some concerns but I found them to work properly at this time. Unit in heat pump mode has 30 degrees temperature rise across the air coil. The coil could benefit from a Blue Tube ultra violet light. I checked the electrical wiring and electrical systems, all are within specification except I found the voltage distribution system to be badly burnt on the left side. I explained to the customer this problem and it’s potential to seize up but customer not interested in having the repairs made at this time. The unit is operating normal but there were minor repairs needed.

Near Park Ln, Pasadena, MD 21122
mattg@supremeservicetoday.com

mattg@supremeservicetoday.com

Replace cartridge on moen valve

Near Marble Arch Dr, Pasadena, MD 21122
Daniel S.

Daniel S.

Arrived due to unit 11 over cash office no heat. Inspected unit in heat test mode found unit to be running properly. Found issue to be with the ducting. Room with tstat getting warmer. the cash office is to far from unit and is the last register farthest from unit. Dampers are need to increase air flow for the long run. Waiting qoute.

Near Ritchie Hwy, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Up on arrival performed fall maintenance on 12/02/2019. Tested thermostat for operation, tested system for operation. Changed air filter that was provided by the customer. Checked all electrical components on air handler and condenser heat pump. Measured delta temperature difference between supply trunk line and return trunk line , Checked drain line. System operating normal at this time.

Near Riverside Dr, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Inspected heat pump unit found bad blower moter. Blower locking up needs replacement. Customer is going to review price and see if they want to replace. They will contact office if they want us to replace.

Near Dwight Dr, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

It’s a heat pump without auxiliary heat strips. I replaced the transformer in the attic and the thermostat the customer had bought worked in cooling but not heating. I installed Honeywell T4 thermostat and tested the unit. Unit heating with 30 degrees temperature rise. Unit operates normal. There is thermostat wire for a heat kit and a 60amp breaker. I quoted installation of 10KW heat kit. Customer asked to have estimate emailed. Customer paid with a check which was mobile deposited.

Near Solley Rd, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned it ,checked coils,filter,cap,Contactor,water pressure.unit operating normal

Near Poplar Ridge Rd, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Arrived to inspect hanging reznor unit for heat test mode. Inspected unit and found wire for spark igniter loose and not allowing ignition. Reseated wire on igniter and reset unit. Reznor heater now running properly

Near Ritchie Hwy, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Arrived to inspect hanging heater reznor unit. Inspected tstat that was blank. Found unit shut down. Reset unit and tested found controls board to be internally shorted and need replacement .

Near Ritchie Hwy, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Fall pm on 11/12/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked air filter cleaned checked blower motor checked coil checked all other electrical connections in door unit checked condenser unit outdoor checked electrical connections checked compressor capacitor checked voltage and amps checked coil checked pressure and temp they are ideal indicating zero leaks c hecked all other electrical connections unit tested unit operating normal at this time. Recommended uv lights installation and single or hole house surge protector installation to avoid future problems also customer she is going to get air filter we have to come back to replace the air filter collected $89 for return visit to replace air filter.

Near Crimson Ct, Pasadena, MD 21122
Christopher A.

Christopher A.

I replaced the air filters with ones provided by the customer. I pressurized the ground loop to 65psi. I checked the electrical wiring and electrical systems, including the auxiliary heat strips, all are within specification. Unit #2 has normal temperature rise and heat of extraction but unit #1, the 2 ton split system has low heat of extraction and temperature rise. I switched it to cooling just to rule out a stuck heating txv but the delta was low in cooling mode as well. Refrigerant leak suspected. I went over options and process with the customer. Customers return home mid November and will schedule a leak search then. I will put in for the office to follow up.

Near List Ave, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Up on arrival performed fall maintenance on 10/30/2019. Checked all thermostats for operation, all units for operation. Tested all electrical components. Found each unit has low voltage absorption, upper unit 10uf - Actual 9.1uf , lower unit 15uf actual 14.2uf , recommended to customer to replace them , also recommended to clean blower motor wheel upper and lower system. Unit working properly at this time.

Near Swift Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

Fall pm on 10/24/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked air filter cleaned checked blower motor checked coil checked EWP and LWP also water temp checked all other electrical connections unit tested unit operating normal at this time. Recommended single or hole house surge protector and UV lights installation to avoid future problems.

Near Patapsco Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

Service call on 10/17/19 On arrival customer explained to me what happened I checked the indoor air handler checked electrical connections checked voltage and amps checked the drain pipe is clogged also the Evaporator coil pan is leaking water is cracked and the duct work is damaged air is leaking out I was explained the customer deferent option to fixed the unit also I was explained how old the unit and never serviced customer she doesn’t want keep fixing the unit she needs to replace the unit and more tones the one she has is not enough for her she needs more the unit she has now Nationalcomfort heat pump 22 years old.I scheduled the customer for tomorrow afternoon 12 to 4 for comfort adviser to gave her estimate. Collected $124 for diagnostic fee on C.C.

Near Bay St, Pasadena, MD 21122
Christopher A.

Christopher A.

The air filter was still very clean. I checked the electrical wiring and electrical systems, all are within specification including the 10kw auxiliary heat strips. I pressurized the ground loop to 65psi. I operated the unit on compressor #12 heating mode and recorded 25-30 degrees temperature rise. I set the flow rate and then calculated the heat of extraction and compared to printed data. Unit operating normal.

Near Holmewood Dr, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Up on arrival performed fall tune up . Inspected entire system. Everything is work really good.

Near Creek Blvd, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Customer broke clogged toilet when in route Plunge water closet and auger

Near Magnolia Ave, Pasadena, MD 21122
Youssef  D.

Youssef D.

On arrival found mr matteson had cleaned his clogged drain line .i then recommended installing a wet switch.custmer approved it .i installed new wet switch.tested the operation of it .unit operating normal.

Near Park Ln, Pasadena, MD 21122
Marc M.

Marc M.

Job is complete we replaced the water heater and added a expansion tank with new pan also. We also replaced the dual check valve with atmospheric vent and comboed with a prv for main boiler system. Bled all air from everything I could bleed. No leaks and already before departure hot water was coming from faucet.

Near Riverside Dr, Pasadena, MD 21122
Marc M.

Marc M.

Prv (pressure reducing valve) valve on boiler system had ilregular pressure is coming into boiler now because the prv is not working correctly so it’s purging itself onto the floor. After replacing valve this will fix the problem of the link. Replace prv on boiler on replace water heater with a new expansion tank and pan for a 50 gl electric.

Near Riverside Dr, Pasadena, MD 21122
Youssef  D.

Youssef D.

On arrival found system locked on bad cap.replaced it .tested system pressures .amps ,unit operating normal

Near E Shore Rd, Pasadena, MD 21122
Christopher A.

Christopher A.

Installation of Amana Heat Pump Air Handler MN# ASPT37 Heat Pump MN# ASZ160361 Total Job$ 6605 Check deposit $3300 Balance due at completion of install $3305.00 Hilmer to collect balance. I helped get the installation wrapped up to satisfaction.

Near Crimson Ct, Pasadena, MD 21122
Yonas M.

Yonas M.

Spring Pm on 08/15/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked air filter checked compressor capacitor checked EWP and LWP also temp checked all other electrical connections in side water furnace unit operating normal at this time. Recommended duct needs to be cleaned.

Near E Shore Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

GEO water furnace spring Pm Pasadena Md

Near E Shore Rd, Pasadena, MD 21122
Pasadena, MD - GEO water furnace spring Pm Pasadena Md
ALEX K.

ALEX K.

paying outstanding balance for service agreement.

Near Park Ln, Pasadena, MD 21122
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

On arrival found Return air temp: 68 supply air temp: 46. System is cooling efficiently, suspect cause for temperature fluctuation is downstairs has no input on thermostat, suggest possible solution is to rework ductwork to make house multi zoned to regulate basement temp independently. Think lack of shade and possible insulation issues could be source of excess heat gain on house since unit is cooling so efficiently. Was asked to check evaporator coil, found slight bacterial growth but don’t think enough to effect health of system. Would recommend coil cleaning if customer has health issues and would like it to be spotless. Coil would have to be removed for coil cleaning. Another option to help with bacteria in air would be uv light installation.

Near Garden Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain cleaned checked air filter no air filter in the unit customer no about it unit needs air filter ASAP checked condenser unit outdoor checked electrical connections checked voltage and amps checked coil checked pressure and temp and they’re ideal indicating zero leaks checked all other electrical connections unit operating normal at this time.

Near Garden Rd, Pasadena, MD 21122
Christopher A.

Christopher A.

Upon my arrival I found unit #1 faulted on high pressure. I reset the unit and had 90 degree entering water temperature and 129+ leaving. I turned the system off and found the flow centers for each unit. The valves were 95% closed for each unit. I opened them fully and removed it the valve handles and placed them on top of the flow centers. I ran both units and bled air from the pumps. I then pressurized the ground loop to 65psi. The pumps were cooling off with water flow restored but more importantly the loop water was cooling down. By morning the loop temperature should be back to 50-55 degrees. As it is now it is operating with higher temperatures than normal but they are dropping and they are not in danger off faulting out. I cleared the fault codes from both units. Units are operating normal.

Near Poplar Ridge Rd, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I found main floor thermostat set for 80 and currently 67, 2nd zone set for 70 and currently at 70 and cooling. Found main zone airflow is still bleeding out of registers. Went to unit and removed entire damper assembly. Found that I had set the setscrew in the wrong position and damper wasn’t closing hardly at all. Verified with entire damper assembly removed from duct that actuator closes damper entirely when shut. Put damper back into duct and returned power to unit. Set thermostat back to 70 degrees at both zones. Main floor zone damper is definitely working, no airflow being fed to zone when satisfied. Also when inspecting the system I found the basement isn’t zoned off like the rest. 12x12 duct has manual damper but customer didn’t know that it was there, thought it was tied into the main zone. Customer wanted to find out if basement zone was supposed to be tied into zoning during installation. For now, I shut basement registers to feed more air to demanding zo

Near List Ave, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival customer showed me error on thermostat, e7. Plugged in aid tool and found e7 is condensate error. Removed panel to find tray full. Maintenance as just completed the other day. Cleared clog and tested drain, clear. Went back to thermostat and called for ac. While inspecting the system I found manual bypass humidifier damper open, closed for summer, open for winter. Finally customer explained that main floor unit was overshooting setpoint. Found damper actuator wasn’t aligned correctly, may have vibrated loose, aligned properly for fully open and fully closed on demand. Verified operation. Finally customer explained that fan only function wasn’t working. Tested intermittent and continuous modes. Found system didn’t cycle fan right away in continuous. Went thru installation settings, reset then reprogrammed. Set staging to faster 1 (only difference in settings) and fan only operation started working. Informed customer to call us if he has anymore problems.

Near List Ave, Pasadena, MD 21122
Youssef  D.

Youssef D.

On arrival set units to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections inspected drain and cleaned it,also checked water pressure .replaced caps,checked Contactors,blowers ,units are operating normal

Near List Ave, Pasadena, MD 21122
ALEX K.

ALEX K.

SA balance for year after monthly was repeatedly taken out when customer requested annual

Near List Ave, Pasadena, MD 21122
Christopher A.

Christopher A.

Upon my arrival I connected to the air handler board via the Cool Cloud app. I found the outdoor unit was not set up correctly. I went through and set system to matched airflow for a 2 ton system and added 12oz refrigerant to obtain 6-8 degrees superheat and 20+ degree delta temperatures across the evaporator coil. I did increase the airflow by 300 cfm to help distribute the air to the upstairs as much as possible without diminishing the capacity of the system. I called installation manager to discuss my findings. Unit operating normal.

Near Seaford Ct, Pasadena, MD 21122
MarkM@supremeairllc.com

MarkM@supremeairllc.com

Blower motor is not amping up in the cooling mode. Changed the constant fan setting from 30 to 70 percent to have proper CFM. Thermostat starts and stops the unit properly.

Near Seaford Ct, Pasadena, MD 21122
Youssef  D.

Youssef D.

Replaced capacitor, system now operating. System under heavy load from house however temps leaving evaporator dropping.

Near Castine Ct, Pasadena, MD 21122
Youssef  D.

Youssef D.

Upon arrival found compressor not running, tested capacitor found capacitor rated for 30 and only at 15.4. Suspect failed capacitor is keeping compressor from running. Do not have any capacitors on truck to confirm. Must come out tomorrow with parts to test and ensure system operating with good capacitor. Customer already paid for capacitor replacement.

Near Castine Ct, Pasadena, MD 21122
Youssef  D.

Youssef D.

Clean blower and housing with a brush and nitrogen. Vacuumed up floor work area.

Near Harlem Rd, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival we started by removing water from loop with flush cart. Then removed flow center from wall mount. Prepped the brass fittings and set the new flow center in place. Piped new fittings in and sealed. Then connected hoses on the bottom. Once flow center was in place and piped together we added water to flush cart and then ran it to flush air out of system. During flush we checked each fitting and found no leaks. Used insulation to cover all piping. Wired in new pump and checked voltage. Once we verified all air was removed we pumped up system to 40psi and ran ac and checked operation. While testing system we cleaned up space. Verified work with customer and checked back on unit. Unit operating normal at this time.

Near Park Ln, Pasadena, MD 21122
Yonas M.

Yonas M.

Service call on 06/03/19 On arrival customer explained to me what happened I put my gauge to outdoor unit no refrigerant is the unit is leaking some where I gave quote for customer to pressure with nitrogen finding the leak also I explained the customer replacement the unit bc the unit never service and is taking R22 is 15yers old customer he is agree with me to replace the unit Chris he was here out Friday he has all the information customer he needs the estimate by today to decide what he is going to do also we have to replace the line set bc the liquid line to small.Collected $99 trip fee and $116 diagnostic fee total $215 on cc when custome by the unit from us he will get that money back.

Near S Shore Pkwy, Pasadena, MD 21122
Youssef  D.

Youssef D.

On arrival found system not operating,found bad cap,i then replaced it and added hard start kit.unit came back on ,checked pressures ,unit operating normal

Near Swift Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

customer was not home didnt answer phones several attempts made within the time frame // text, phone calls, to no avail yonas left a note for customer to call the office and reschedule because he went to the home and there was no answer at the door

Near Creek Rd, Pasadena, MD 21122
Youssef  D.

Youssef D.

Water leaking from the pump assembly. May need to have it replaced.

Near Park Ln, Pasadena, MD 21122
Youssef  D.

Youssef D.

On arrival set thermostat to call for cooling. Measured return temperature, supply temperature, amps,and voltage. Measured EWP,LWP,EWT, and LWT. I pressurized system to 60psi. Inspected electrical connections, contactor, blower wheel is clean,replaced filter provided by customer, tested condensate pump, cleaned condensate pan as well as the condensate drain line. Measured voltage absorption system rated for 80mfd. Actual reading 80.06mfd. I found dirty evaporator coil. Customer approved quote to clean evaporator coil. $284.75 Credit card payment. Customer renewed service agreement $299.00 credit card payment. Customer paid total of $583.75. I also recommended to get their duct cleaning, they will contact the office to schedule an appointment. Estimate for duct cleaning $521.90. Unit operating correctly at this time.

Near Poplar Ridge Rd, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I went to system and shut off power. Removed old zoning panel and installed new one. Then replaced each thermostat. Finished installation by wiring in Humidistat. Returned power to system and tested heat and ac on all zones. Verified normal operation of HeatPump, Zone Panel, Thermoatats, and Dampers. Showed customer how to operate system. Unit operating normal at this time. Per office, customer prepaid for service.

Near Royal Beach Rd, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I found main floor system heating, informed customer that when switching modes to make sure the unit “beeps” and matches the correct temperature on the display as the remote. Verified normal operation once system switched over from heat to ac. All units operating normal. Also showed customer how to adjust vane and fan speeds.

Near Harlem Rd, Pasadena, MD 21122