Severn, MD Air Conditioning, Heating and Plumbing Services

Supreme Service Today provides Air Conditioning, Heating and Plumbing Services, Repair, Installation, Maintenance, and Tune Up in Severn, MD and surrounding areas.

Check out what some of our customers are saying about Supreme Service Today.

Local Reviews
for Severn, MD

Supreme Service Today Rated 5.0 out of 5 stars based on 3 customer reviews

Map of Severn, MD

Give Youseff a RAISE!




Review of Supreme Service Today

Youseff nice guy very professional. Not happy with 1st pricing during summer. I knew for a fact I just needed Freon but you guys made me do a leak check when the unit was only 2 yrs old for $350 and of course no leak. I did not like that! After spring inspection which I already paid for I will be looking else where. Again Youseff did a good job and very knowledgeable Thank you


Map of Severn, MD

Great




Review of Supreme Service Today

Really great service, had unrelated problem and they solved it at no extra cost, see Phill 💯


Map of Severn, MD

Awesome, professional service




Review of Supreme Service Today

Excellent, prompt service - very knowledgeable and friendly professional at all points of the transaction, from dispatcher to completion. Will definitely go Supreme if we ever need plumbing services again!


nikolayn@supremeservicetoday.com

nikolayn@supremeservicetoday.com

Up on arrival performed winter maintenance on 12/30/2019. Checked thermostat for operation, checked system for operation. Checked all electrical components. Took readings of delta T, P. Changed air filter s413. System operating normal at this time.

Near Council Oak Dr, Severn, MD 21144
chrisa@supremeservicetoday.com

chrisa@supremeservicetoday.com

I replaced the vs loop pump and made electrical connections. I then flushed from flow center to the equipment to purge any air. I restored power to the unit and once the unit began heating there was a pressure drop noted and 11.6gpm flowrate and 36,000+ btu/hr heat of extraction, which matches the printed data sheet. I pressurized the ground loop to 65psi with the manual loop pump. Unit operating normal, no fault codes. I noticed the outdoor faucet has not been updated to the freeze proof faucet. I’m sending an estimate for installation of one.

Near Pasture Brook Rd, Severn, MD 21144
youssefd@supremeservicetoday.com

youssefd@supremeservicetoday.com

On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked blower,filter,thermostat,safeties.unit operating normal

Near 4th St, Severn, MD 21144
Yonas M.

Yonas M.

Tuneup on 12/09/ 19 On arrival I sanded the flame rectification probe and checked burner arrangement the ignitor homes out to be in good condition checked all other electrical connections set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain checked filter checked blower motor checked all other electrical connections checked temp rise DT 30.6 made for 20-59 unit tested unit operating normal at this time. Recommended Uv lights installation and DUCT Cleaning also Wet switch And Ez trap installation to avoid future problems.

Near Horsedrawn Ct, Severn, MD 21144
colint@supremeservicetoday.com

colint@supremeservicetoday.com

Upon arrival I removed pump from system before Niko arrived. When he arrived we found that we have the wrong pump, was given fixed speed pump when we need variable speed. Called office to inform them. They are expediting Pump.

Near Pasture Brook Rd, Severn, MD 21144
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Service call on 11/25/19 On arrival the thermostat is blank I go to the unit checked electrical wires checked electrical connections checked voltage I have high voltage comes in to the unit but no low voltage checked thermostat wires checked fuse I found is burnt I put reset fuse tested checked voltage and amps measured supply and return air unit operating normal I take the rest fuse i gave quote for customer also I gave customer -$50 hvac service discount customer accepted the quote I replaced old fuse out i put new 3amps fuse in tested unit start operating very smoothly without any hesitating or lag I put my aurora tools no fault unit normal checked electrical connections checked voltage and amps checked EWP and LWP also water temp measured supply and return air temp unit operating normal at this time.

Near Merriweather Way, Severn, MD 21144
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Fixed leak on Half-inch CPVC coupling underneath kitchen sink on hot side apparently glue didn’t hold or wasn’t enough

Near Calder Way, Severn, MD 21144
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Inspected units in heat test mode to verify proper operation. Inspected pressure and temp of water lines. Inspected all motors for proper amp draw.Units running properly. Inspected humidifier and cleared drain line and humidifier is operational. Job complete

Near Merriweather Way, Severn, MD 21144
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Found packing nut leaking. I took it apart and Teflon taped and pipe dope the connections and waited around for a bit to make sure there is no more leaks this turn around after turning water back on. Warranty service

Near Calder Way, Severn, MD 21144
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Tighten packing nut on supply line to faucet in kitchen and remove soap dispenser. Tested and found no other leaks.

Near Calder Way, Severn, MD 21144
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Fall pm on 11/18/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked air filter cleaned checked blower motor checked coil checked EWP and LWP also checked water temp checked all other electrical connections unit tested unit operating normal at this time. Recommended Duct cleaning And UV lights installation also single or hole house surge protector installation to avoid future problems.

Near Thompson Ave, Severn, MD 21144
Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com

Up on arrival found bad water circulation pump on WaterFurnace 7 . Called WaterFurnace tech support, spoke with tech support and verified that water pump is bad .

Near Pasture Brook Rd, Severn, MD 21144
Colin T.

Colin T.

Replace ECM blower motor for Unit #1. Upon arrival I went to packaged 7 series unit and shut off power. Removed wiring harnesses from system then removed blower assembly from mount. Removed motor from Assembly and replaced with new. Mounted assembly with new motor into unit and wired system back together. Returned power and ran blower only on all speeds. Then tested ac and heat to make sure we had proper operation.

Near Montecristo Ct, Severn, MD 21144
Youssef  D.

Youssef D.

On arrival found system operating normal ,checked delta t. Safeties ,heat exchanger.also cleaned drain .unit operating normal at this time

Near Spaulding Cir, Severn, MD 21144
Christopher A.

Christopher A.

ECM blower motor has line voltage and control voltage but is not operating. It tries to start up but something in the internal electrical system has become faulty and the blower will not operate. I called the customer and they approved replacement of the blower motor. I filled in a parts order form so that the motor can be ordered from Water Furnace asap. I did make sure the variable speed pump was working. Customer paid $386 today with $386 due upon completion of the repair. Customer had to leave upon my arrival. If there is a surge protector installed then disregard the estimate I will send for a whole house surge protector. Sometimes a surge can damage these motors.

Near Montecristo Ct, Severn, MD 21144
Yonas M.

Yonas M.

Fall pm on 10/02/19 On arrival set units to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked air filter and replaced checked EWP and LWP it was low I pump it back up to 50/42 psi checked water temp checked compressor capacitor checked coil checked blower motor checked all other electrical connections in side the unit tested unit operating normal at this time. Highly recommended for Unit #1 Uv lights installation For Unit #2 Uv lights installation also duct cleaning and wet switch to avoid future problems.

Near Montecristo Ct, Severn, MD 21144
Yonas M.

Yonas M.

Fall pm On 09/13/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked air filter and replaced checked EWP and LWP also temp checked blower motor cleaned checked all other electrical connections checked heater package cleaned unit tested unit operating normal at this time. Recommended Uv lights needs to be installed.

Near Council Oak Dr, Severn, MD 21144
Yonas M.

Yonas M.

Fall pm On 09/13/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked air filter cleaned checked EWP and LWP it was low I pump it back up to 67/59 psi checked water temp checked electric heat is cleaned I found connections but of the blower motor I explained the customer but customer he told me he set the thermostat the fan motor running every 15 seconds I’m suggesting to but the fan to auto to solve future problems checked all other electrical connections unit operating normal at this time. Recommended surge protector for hole house or for Geo.

Near Elberta Dr, Severn, MD 21144
ALEX K.

ALEX K.

Paying off outstanding Balance for April to July 29.15 monthly payments,

Near Sea Pine Cir, Severn, MD 21144
Marc M.

Marc M.

Customer will be in contact wether or not she will complete the work. Upon arrival found the elements not burning or firing up. Found no humming coming from unit. Which is a clear sign of them not working if power is ran to them. Would suggest replacing the elements and go from there.

Near Carinoso Way, Severn, MD 21144
Marc M.

Marc M.

Paid 60 will talk with wife about the inspection. Upon arrival found the kitchen sink line clogged would suggest a camering due to the house being on a slab and there could be a dreakage after 35 ft.

Near Chalice Rd, Severn, MD 21144
TomB@supremeairllc.com

TomB@supremeairllc.com

Showers not working in basement believe screens are clogged to showerhead tighten up three toilets locate shut off valves for hose bibs attempt to flip cartridge on shower in master to reverse hot and cold Replace prv valve and check sump pump To make sure it is working correctly Replace main ball valve

Near Hatboro Ct, Severn, MD 21144
Christopher A.

Christopher A.

I spoke with installation manager and sales person regarding the fact that the oil furnaces transformer was not producing control voltage. I was told to replace the transformer to get the unit operational. I then operated the unit on cooling mode and checked the refrigerant pressures and added 10-12oz of r410a to achieve 4-8 degrees superheat and 20+ degree delta temperatures across the evaporator coil. Unit operating normal.

Near Clark Station Rd, Severn, MD 21144
Yonas M.

Yonas M.

I was talking to the customer she told me her unit is fixed she doesn’t want the service

Near Pioneer Dr, Severn, MD 21144
Yonas M.

Yonas M.

Service call on 07/22/19 On arrival set unit to call for cooling the unit is tripped wet switch reset it checked electrical connections checked voltage and amps measured supply and return air temp checked air filter checked condenser drain line is clogged I gave quote for customer cleaned the drain line with nitrogen and vacuum the drain line she accepted the quote cleaned the drain vacuum it tested water is running out normal checked electrical connections checked voltage and amps measured supply and return air temp unit operating normal at this time collected $89 dispatch fee and $283 for cleaning the drain line with nitrogen total $372

Near Severn Tree Blvd, Severn, MD 21144
Christopher A.

Christopher A.

I recovered the refrigerant, removed the sticking txv and refrigerant filter drier. I brazed in the new txv and filter drier. I pressurized with dry nitrogen to 250psi and let hold pressure and then flushed the lineset from high side to low side. I pulled the system into a <500 micron vacuum and charged the system until I had 10 degrees subcooling, normal refrigerant pressures and 23-24 degree delta temperatures across the evaporator coil. Unit operating normal. Customer paid remaining balance.

Near Council Oak Dr, Severn, MD 21144
Marc M.

Marc M.

Snake main line. Main line clogged will also snake from kitchen to fully clean lines.

Near Jacobs Meadow Dr, Severn, MD 21144
Christopher A.

Christopher A.

Upon my arrival the unit was running in cooling mode. I had 75 return and 60 supply, which is only 15 td. I went to the outdoor unit and applied my refrigerant gauges and had low suction and low discharge pressure with both high superheat and subcooling. I isolated the sensing bulb and in the process of doing that noticed a large puddle of water in the bottom of the duct under the coil. Heating and cooling the bulb resulted in little to no change of suction pressure and as the unit runs the subcooling gets higher and higher. The unit need to have the txv valve replaced. Customer approved this repair and paid $600. I completed a parts order form for the parts needed. I told the customer the office will call to schedule return visit to fix the system. The unit is operating some so customer does have some cooling in the meantime.

Near Council Oak Dr, Severn, MD 21144
Youssef  D.

Youssef D.

On arrival found system not working correctly,found system had leaked out all the refrigerant.i then presssurized system with nitrogen ,I couldn't find any leak .pressure held at 350 ,also vacuumed system and held at 500 microns .i recharged system with 67oz of 410 ,tested it ,unit operating normal

Near Telegraph Rd, Severn, MD 21144
Youssef  D.

Youssef D.

Diagnosis of tapping sound not plumbing related.

Near Coolidge Ave, Severn, MD 21144
Yonas M.

Yonas M.

Spring Pm on 05/17/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter and replaced checked in water pressure and out water pressure also checked water temp checked all other electrical connections unit tested unit operating normal at this time.

Near Council Oak Dr, Severn, MD 21144
Yonas M.

Yonas M.

GEO water furnace spring Pm Severn Md

Near Council Oak Dr, Severn, MD 21144
Severn, MD - GEO water furnace spring Pm Severn Md
Youssef  D.

Youssef D.

On arrival set unit to call for cooling. Measured return temperature, supply temperature, amps, voltage, EWT,LWT,EWP,and LWP. Inspected electrical connections, filter is clean, evaporator coil is clean, blower wheel is clean, pressurized system to 60psi, cleaned condensate drain line and condensate drain pan. Unit is operating normal at this time.

Near Merriweather Way, Severn, MD 21144
Christopher A.

Christopher A.

Hot water heater flue pipe was not secured properly and fell off the tank. I mounted it securely and sealed up any cracks or screw holes with aluminum flue tape. I took before and after pictures for warranty reasons.

Near Sea Pine Cir, Severn, MD 21144
Yonas M.

Yonas M.

Spring Pm On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filter cleaned checked condenser unit checked electrical connections checked voltage and amps checked coil checked compressor capacitor checked pressure tested unit operating normal at this time.

Near Horsedrawn Ct, Severn, MD 21144
Philip H.

Philip H.

Installation of Amana Heat Pump Air Handler MN# ASPT37C14 S# 1901050544 Heat Pump MN# ASZ160361 S# 1812167176 Total Job $6454.00

Near Terry Lee Way, Severn, MD 21144
michaelr@supremeairllc.com

michaelr@supremeairllc.com

To replace 50gallon gas water heater , will need ballvalve , and pan expansion tank is still good and looks new , heater is from 1996 Ac unit Coil is rusty and dripping and pan in unit is full of water Installed 50gallon gas water heater also installed ball valve and expansion tank as well

Near Sea Pine Cir, Severn, MD 21144
Youssef  D.

Youssef D.

On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections inspected drain and cleaned it,inspected coils, blower,caps,contactor .unit operating normal

Near Spaulding Cir, Severn, MD 21144
Colin T.

Colin T.

Upon arrival I spoke with customer and him and he didn’t have a problem with furnace, only wanted to get system inspected. He and Donna spoke and it was agreed that for $99 I would inspect his furnace. Capacitor in spec, flame sensor a little dirty but correct spec, ignitor in spec. Inspected heat exchanger, good. Blower clean. Filter has decent amount of dust, customer may want to consider duct cleaning. Ran furnace and found normal heat rise and amp draw. System operating normal.

Near Sea Pine Cir, Severn, MD 21144
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival checked thermostat was calling for cooling. Measured EWP,LWP,EWT,LWT. measured return and supply temperature, amps, voltage, inspected electrical connections, blower wheel is clean, evaporator coil is clean, used a vacuum to clean condensate line, and replaced filter provided by customer Aprilaire 413. Customer is moving out. Unit is operating normal at this time.

Near Thompson Ave, Severn, MD 21144
Daniel M.

Daniel M.

Completed AC inspection .n

Near Elberta Dr, Severn, MD 21144
Colin T.

Colin T.

Upon arrival I found furnace firing up then flame shuts off due to low flame sense. Quoted customer to replace but he declined for now. He may be considering replacing soon, furnace and ac 14+ years old.

Near Pioneer Dr, Severn, MD 21144
Yonas M.

Yonas M.

Fall pm on 02/11/19 On arrival set units to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters unit operating normal at this time.

Near Northwood Estates Dr, Severn, MD 21144
Youssef  D.

Youssef D.

On arrival checked thermostat was calling for heat, inspected EWP,LWP,EWT,LWT, electrical connections, voltage, AMPS, and also replace filte(size413). Unit is operating normal.

Near Council Oak Dr, Severn, MD 21144
Yonas M.

Yonas M.

Fall pm on 02/01/19 On arrival set units to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters and replaced unit operating normal at this time.

Near Blairfield Ct, Severn, MD 21144
Derrick S.

Derrick S.

Vent pipe not secure going thru roof secure vent pipe and reseal

Near Coolidge Ave, Severn, MD 21144
Daniel M.

Daniel M.

Furnace is in the basement with the exhaust going out of the back of them home . Leak is on the first floor ceiling under the washer . Would need to cut ceiling open to find problem . Costumer needs to talk to property owner .

Near Coolidge Ave, Severn, MD 21144
Yonas M.

Yonas M.

Fall pm on 12/06/18 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters recommended to install UV lights unit operating normal at this time.

Near Merriweather Way, Severn, MD 21144
Yonas M.

Yonas M.

GEOTHERMAL WATER FURNACE FALL PREVENTATIVE MAINTENANCE SEVERN MD

Near Musical Way, Severn, MD 21144
Severn, MD - GEOTHERMAL WATER FURNACE FALL PREVENTATIVE MAINTENANCE SEVERN MD
Christopher A.

Christopher A.

The compressor voltage absorption system (run capacitor) was rated for 30 and had a value of 8.36. Therefore the compressor could not start or run. Customer had turned the heat off last night, otherwise the auxiliary heat would have kicked on. I made sure the auxiliary heat strips did operate. I replaced the part with a 30uf single run capacitor with a start value of 30.35. I cycled the unit to make sure it would operate and checked the temperature rise: 25.4 degrees in second stage heat mode, which is within comfort range and units specifications. Unit operating normal. I retained the depleted capacitor to return to Water Furnace. I also spoke with the customer about the Intellistart modules.

Near Pine Cone Ct, Severn, MD 21144